Harmonic suppression unit - メーカー・企業と製品の一覧 | イプロス

Harmonic suppression unitの製品一覧

1~4 件を表示 / 全 4 件

表示件数

Hitachi Industrial Equipment Systems Harmonic Suppression Unit (HS910 Series)

Harmonic suppression unit that converts input current into a pure sine wave, achieving energy savings and power factor improvement.

Overview The input current waveform is shaped into a sine wave, reducing and suppressing the harmonics generated by the inverter. It also helps improve power factor. By returning regenerative energy from the motor to the power supply side, energy savings can be achieved. The HS910 series is equipped with communication functions and lifespan detection features to enhance usability. Additionally, stability has improved in generator combination operations compared to conventional models, achieving resilient operation. The input current waveform is shaped into a sine wave, reducing and suppressing the generation of harmonics. When using a harmonic suppression unit, the power supply circuit in the harmonic suppression measures guideline is treated with a conversion factor K5=0. The issue of peak current occurring in the input current with just the inverter is addressed by improving the input current to a sine wave shape, thereby suppressing the generation of harmonics. Furthermore, controlling with a power factor of 1 also aids in power factor improvement, allowing for the downsizing of power supply equipment. Common converter configuration allows for parallel connection of inverters. Multiple inverters can be connected in parallel to achieve a common converter configuration. This eliminates the need for individual regenerative braking units, allowing for collective harmonic suppression, which results in space savings and cost reduction. Returning regenerative energy to the power supply enables energy savings. When using a braking resistor,

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Hitachi Industrial Equipment Systems Harmonic Suppression Unit HS910 Series

Harmonic suppression unit HS910 series that converts input current into a pure sine wave and suppresses harmonics.

Features - The input current waveform is shaped into a sine wave, reducing and suppressing the generation of harmonics. When using a harmonic suppression unit, the power supply circuit is treated with a conversion factor K5=0. This addresses the issue of peak current occurring in the input current with just an inverter by improving the input current to a sine wave shape and suppressing the generation of harmonics. Additionally, controlling with a power factor of 1 helps improve the power factor and contributes to the miniaturization of power supply equipment. - Common converter configuration allows for parallel connection of inverters. Multiple inverters can be connected in parallel to achieve a common converter configuration. This eliminates the need for individual regenerative braking units, allowing for collective harmonic suppression, which can save space and reduce costs. - Energy savings can be achieved by returning regenerative energy to the power supply. When using a braking resistor, the regenerative energy from the motor is consumed as thermal energy. For further details, please contact us.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Hitachi Industrial Equipment Systems Harmonic Suppression Unit (HS900A Series)

Harmonic suppression unit (400V class) that converts input current into a pure sine wave, achieving energy savings and power factor improvement.

Overview It shapes the input current waveform into a sine wave, reducing and suppressing the harmonics generated by the inverter. It also helps improve power factor. By returning regenerative energy from the motor to the power supply side, it contributes to energy savings. Features - It shapes the input current waveform into a sine wave, reducing and suppressing the generation of harmonics. - It enables common converter configuration, allowing for parallel connection of inverters. - By returning regenerative energy to the power supply, it contributes to energy savings.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Hitachi Industrial Equipment Systems Harmonic Suppression Unit HS900A Series

Harmonic reduction and power factor improvement suppression unit HS900A series.

Features - Converts input current waveforms into a sine wave shape, reducing and suppressing the generation of harmonics. It also helps improve power factor. - Enables common converter configuration, allowing for parallel connection of inverters. - Returns regenerative energy to the power supply, contributing to energy savings.

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録